WE EQUIP YOUR LABORATORY WITH SPEED AND EFFICIENCY

HI-931-02 Automatic Potentiometric Titration Systems

The Automatic Potentiometric Titration Systems is designed to perform a wide variety of potentiometric titrations with high accuracy and flexibility, allowing the user to obtain both accurate results and high-speed analysis.

  • pH
  • New Compact Design

£6,084.50 exc. VAT

Product Code: SSHNH049 Category
hanna-instruments-logo

Description

The titrator can perform fixed endpoint or equivalence point titrations and direct measurements by measuring the pH/mV and temperature of the sample.

Reports and materials can be transferred to a PC via a USB interface, saved to a USB storage device or printed directly from the titrator. An external keyboard can also be attached for added convenience.

 

Main features at a glance

  • Small footprint, requires minimal bench space
  • Casing made with strong, chemically resistant plastic
  • Flexible electrode holder supports up to 3 electrodes, 4 dispensing tubes, 1 temperature sensor and removable stirrer
  • Electrode holder positions electrodes in the centre of the beaker, allowing for smaller sample sizes
  • Integrated Peristaltic Pump available for reagent addition
  • Support for 100 titration methods and 30 autosampler sequences
  • User-customisable reports
  • Integrated research grade pH/mV/ISE meter
  • Clearly displayed warning and error messages
  • Titrator capabilities

 

Dynamic titrant dosing

The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.

Equivalence endpoint detection

Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.

Signal stability timing

The signal stability feature monitors when the mV response of the titration reaction stabilises before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.

Multiple titration types

Paired with the right electrode from our sensor line, our potentiometric titrators can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations.

Direct measurement functionality

The HI-931 performs as a high accuracy pH, ORP, and ion selective meter that can link, log, and report direct measurements. Users can easily track and manage data without the hassle of manual record keeping.

Burettes and dosing system

Exchangeable burette system

With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.

Multiple burette sizes

The HI-931 comes supplied with a 25mL burette but may be equipped with a 5mL, 10mL or 50mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.

Precision dosing pump

Our unmatched 40,000 step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.

Automatic reagent addition

A peristaltic pump or a second burette may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition.

Redesigned electrode holder

Spring-loaded actuator allows you to quickly raise or lower the stirrer/electrodes with the push of a button

Space-saving geometry allows for sample sizes less than 50mL

Support rods mount directly to the titrator – no need for special mounting hardware

Peristaltic pumps

Add reagents to your samples automatically before every titration using integrated peristaltic pumps

Redesigned burette well

The burette well is sealed on the bottom to catch drips and spills

 

 

Methods of analysis

Customisable methods

These titrators can store up to 100 user-defined or standard titration and direct measurement methods. Each method may be modified and optimised for performance based on application and user requirements.

Titration method support

Onsite installation, training, and customisation is available from one of our product specialists. Hanna offers continued support for any questions you might have along the way.

Market specific methods packs

Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more.

Data Storage

Up to 100 titration and pH/mV/ISE reports. Transfer data via USB.

Flexible GLP management

All necessary GLP (Good Laboratory Practice) information can be recorded with each sample.

 

Connectivity and functionality

Multifunctional

The titrators also function as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.

Multiple Connections

The HI-931 offers support for one analog board to allow an electrode, up to two burettes, and a stirrer to be connected to one unit simultaneously.

Interface and display

Interactive colour display

A large, colour LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values.

Detailed titration graphs

A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimisation.

 

Fully customisable titration methods

Titration graphs

Titration graphs can be viewed on-screen or saved as images and transferred along with titration report.

Customisable reports

Data to be stored in titration reports is fully customisable.

Additional information

Manufacturer

NEED HELP ?

Fill in the form and our team of experts will recommend the best viscometer and setup based on your requirements.