Description
Features and Benefits



3 Year Warranty
Before leaving the factory, every water bath is identified with a unique serial number and undergoes a factory calibration, adjusting the control to a known traceable value. Each is electrically tested for safety during the final inspection, and a test certificate is enclosed in the rear of the instruction book.



The shelf in the stainless steel tank provides a stable support for flasks/bottles/racks that can be removed for cleaning.
The shelf is a low height design maximising the working height.
Broad range of accessories available to suit wide range of applications.
Painted surfaces feature “anti-bacterial technology” which inhibits bacterial growth, improving hygiene requirements as demanded by clinical and laboratory environments.
Safety Features
Thermal cut out fitted in the heater.
IP rated clear booted on/off power switch.
Bath fitted with non-slip rubber feet.
Over temperature alarm automatically set 4˚C above set temperature with visual indicator and heating is turned off protecting samples from overheating.
Product Highlights

Energy Consumption
0.2kWh @ 37°C
0.21kWh @ 60°C – lid fitted
(Based on NE2-4D)
Please note that energy consumption may vary due to factors such as location, ventilation, ambient temperatures and loading.

Controls
Each water bath features a bold LED display of measured temperatures in real-time and in increments of ±0.1°C, using a precision PID temperature controller. Option to set for water temperature only or a combination of temperature and time. Timer setting variable in 1-minute increments from 00:01 to 99:59 (hh:mm). Time and temperature settings are retained in the memory, even after the unit has been turned off. Every bath undergoes a factory calibration at 37°C and 85°C for validation.

Heating/Cooling Information
An accessory immersion cooler DC1-300 is used to cool the water bath. Where bath temperatures are below ambient, we recommend a mix of glycol and water. We also recommend a lid or layer of spheres for insulation. The water bath should be used in ambient temperature (20°C). For water temperatures above 60°C we recommend that an accessory lid or layer of spheres be used for optimum performance. This will reduce evaporation and a lid will keep the samples and water free from contamination. Optimum performance saves energy by reducing electricity consumption and running costs.

Heating and Sensors
Heaters and temperature sensor are concealed under the tank providing an easy to clean working area. The heating footprint covers the underside of the tank and with a low mass provides rapid energy transfer, resulting in quicker heat up times and a reduction in energy consumption and improved temperature uniformity.