WE EQUIP YOUR LABORATORY WITH SPEED AND EFFICIENCY

1200XL Classic – Ductless Fume Hood – Class 2

The ductless fume hoods in the Classic range are ideal for eliminating contaminating gas and/or solid particles/aerosols from the work space simply and efficiently. Safe, efficient and cost-effective, these protect both the user and the environment.

This range is unassembled when delivered so that it can be easily placed in any laboratory (despite narrow corridors, cramped stairways or ones that are difficult to access, etc.), substantially reducing transportation costs.

All the models in the Classic range use the new filtration system, developed and patented by Cruma (Invention Patent), which ensures the contaminating gas, fumes and particles generated inside are retained, thus constantly renewing the air inside the laboratory. The main advantages offered are:

Call for Price

Product Code: CR1200XL G/GS Category
Cruma_logo

Description

Personnel Safety

Apart from completely protecting the person handling the material inside the cabinet, the chemical toxins produced are not released to the outside but remain inside the cabinet thanks to the filtration system formed by a variety of activated carbon filters.

Flexible

These can be used in areas where it is difficult to extract contaminated air, such as the lower floors of buildings, and they can be placed in different locations, which it means that they can be easily relocated if needed.

Economic Savings

The innovative system removes the need for expensive work is necessary to install conduits to extract the gas to the outside which means there are no additional costs and no need to interrupt a laboratory working at full capacity.

Energy Savings

Unlike traditional extraction hoods, our fume hoods do not use the air conditioning equipment inside the lab, which substantially reduces energy costs. The aspirated air is not expelled outside but recirculated back into the lab free from contaminating substances.

870 PF G MV 1 10 scaled e1741336173697

Classic Range Features

More information on the new LCD display

  • New size 127x34mm display
  • Air speed continuously monitored
  • Type of filter installed, working hours, expiration date and next revision date
  • Open door warning through electronic photocell
  • Countdown timer
  • Clock and calendar

 

New features and components

  • Initial air flow cycle adequacy and final purge cycle
  • Fault LED
  • Control of air flow through Microprocessor
  • Activated carbon filters with electronic chip
  • LED illumination

 

New alarms and scheduled warnings

  • Open door warning
  • Open door in off mode warning
  • 60h of filter use warning
  • Next validation warning
  • Few hours of filter life warning
  • Countdown timer w  arning
  • Expired filter alarm (by hours)
  • Expired filter alarm (by date)
  • Temperature alarm
  • Equipment without filter alarm
  • Low barrier alarm

870 PF G BASE 10

Plug & Play System 

The fume hoods in the Classic range were designed to reduce transportation costs, as, once delivered, all you have to do is take them out of their fantastic packaging, assemble them easily in the desired spot, plug them into the mains and get to work. As easy as that, straightforward and hassle-free. What’s more, they can be placed anywhere because they can be dismantled!

All of the Classic fume hoods use the new filtration system, developed and patented by Cruma (Invention Patent no. 2397598), which protects the operator by retaining the contaminating gas, fumes and particles generated inside, constantly renewing the air inside the laboratory and avoiding leaks that may contaminate the environment.

Classic Range Specification

Equipment Description
Electronic circuit with large format LCD screen Security levels: level 1 for users and level 2 for maintenance users
Electronic anemometer device Electronic sensor monitoring continuously air face velocity
Photocell sensor device for open door detection Electric device with open door alarm
Electronic control device for filters replacement The filters incorporate a microchip with miniUSB connection that identifies the type of filter installed, the expiry date and the serial no.
Illumination 96 LED Tube high light intensity and low power consumption – 16 Watts / 700 Lux
Sampling system to analize the filtered air at the exhaust To detect the level of filter saturation
60 hours alarm Countdown timer according to French NF X 15-211:2009
Electronic cronometre with audible alarm To program the work inside the fume hood
Clock and calendar Display of date and time
Working surface 1 Spill retention tray (2-10 liters) with working surface in white tempered glass
G4 Prefilter G4 class pre-filtering blanket of synthetic biofibres  (according to EN-779) for the retention of atmospheric dust
Cable entry holes (2) Access to the rear wall for cables and / or services entry
Chemical Listing Guide of retained products by type of filter
Warranty 7 años

Optional Equipment

Equipment Description
Movilair Stand with wheels and internal tray in Epoxy coated steel
Tubular steel stand Support stand in Epoxy coated steel
Working surface 2 Spill retention tray (2-10 liters) with working surface in phenolic resin
Working surface 3 Spill retention tray (2-10 liters) with working surface in inox steel
Transparent rear back pannel Transparent polymethylmethacrylate rear pannel 8 mm thick (light transmission of 93%). Ideal for teaching sessions.
Voltage / Frequency 125 V / 50 Hz
Filter test kit Dräger pump with reactive colorimetric tubes (pack 10u)

The patented Cruma filtration system is based on the adsorption phenomenon.

Catalogo Cruma 2022 EN 23

Read More about our Filter System

Models and Technical Specifications

A wide range to ensure the air remains clean and health is unaffected

Models and Technical Specifications

Model 670 870 990 1010 1200 1200XL
Internal Sizes (width/depth/high) 576x563x630 776x566x720 976x566x720 976x566x920 1176x760x780 1176x967x1106
External Sizes (width/depth/high) 600x600x937 800x600x1037 1000x600x1037 1000x600x1237 1200x800x1097 1200x1000x1422
Filtration columns 1 1 1 1 1 1
Filter number 1 a 2 1 a 2 1 a 2 1 a 2 1 a 2 1 a 2
Fans 1 1 1 1 1 1
Average volume of treated air/hour 112 m3/h 160 m3/h 160 m3/h 160 m3/h 160 m3/h 160 m3/h
Average face velocity 0.50 m/s 0.50 m/s 0.50 m/s 0.50 m/s 0.50 m/s 0.50 m/s
Internal volume of the cabinet 0.202 m3 0.316 m3 0.398 m3 0.508 m3 0.697 m3 1.258 m3
Renewals inside the cabinet/min. 9.2 m/s 8.5 m/s 6.8 m/s 5.3 m/s 3.9 m/s 2.1 m/s
Total electrical power consumption 57 W 57 W 60 W 60 W 60 W 60 W
Voltage-Frequency 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz
LED light intensity 1300 lx / LED 18 W 1100 lx / LED 18 W 1100 lx / LED 18 W 825 lx / LED 18 W 800 lx / LED 18 W 800 lx / LED 18 W
UV Lamp – – – – – –
Noise Level 55 ± 3 dB 55 ± 3 dB 58 ± 3 dB 58 ± 3 dB 58 ± 3 dB 58 ± 3 dB
Weight 58 Kg 77 Kg 90 Kg 95 Kg 118 Kg 123 Kg
Packaging volume 0.33 m3 0.43 m3 0.52 m3 0.52 m3 0.65 m3 0.65 m3